Pharmacology & Dose-Response Analysis
4-Parameter Logistic (4PL) Hill Fit
Cheng-Prusoff Ki Conversion

IC50 Calculator — 4PL Dose-Response & EC50 Curve Fitting

Calculate half-maximal inhibitory concentration (IC50), EC50, and Hill slope from biological dose-response data using four-parameter logistic non-linear regression. Includes Cheng-Prusoff Ki affinity conversion and interactive curve plotting.

Dose-Response (IC50 / EC50) Regression

Load Preset:
%
%
Assay Data Points
Conc. (nM)Response (%)
Paste tabular data (Conc, Response):
Sigmoidal 4PL Fit Curve
100%50%0%Log₁₀[Concentration] (nM)
IC50 Value
Inhibition %
11.75nM
Hill Slope (n)1.12
Fit Quality (R²)0.9993
IC90 Value83.56nM

IC50 Calculator Formulas: 4PL Model & Cheng-Prusoff Equation

1. Four-Parameter Logistic (4PL) Hill Equation

The gold standard mathematical model for sigmoidal bioassay dose-response relationships:

Y=Bottom+
Top-Bottom
1 + 10(log IC₅₀ - X) · HillSlope

Where X is log₁₀(Concentration), Bottom and Top represent the lower and upper asymptotic plateaus, and HillSlope indicates the steepness of the curve.

2. Converting IC50 to Ki: The Cheng-Prusoff Equation

While IC₅₀ depends on experimental substrate concentration, the inhibition constant (Ki) represents the true thermodynamic binding affinity:

Ki=IC50
1 + [S]Km

Applicable for classical competitive enzyme inhibitors where [S] is substrate concentration and Km is the Michaelis constant.

3. Significance of the Hill Slope (n)

Standard Slope (~1.0)Single binding site following non-cooperative mass action kinetics (one ligand per target molecule).
Steep Slope (>1.5)Positive cooperativity or steep threshold mechanism, ligand aggregation, or solubility drop-off.
Shallow Slope (<0.8)Negative cooperativity, multiple receptor subtypes, or heterogeneous target binding sites.

IC50 Calculator Assay Design & Serial Dilution Quality Controls

Establish Complete Plateaus

Ensure at least 2 concentration points define the upper baseline (0% inhibition) and 2 points define the maximal effect plateau (100% inhibition) to prevent unbounded regression errors.

Even Logarithmic Spacing

Use 3-fold or half-log (3.16-fold) serial dilutions across a 3–4 order of magnitude dynamic range (e.g., 10 nM to 100 µM) for balanced curve fitting.

Solvent / DMSO Vehicle Control

Maintain a constant DMSO concentration (≤ 0.5% v/v) across all wells, including untreated negative controls, to eliminate vehicle-induced cytotoxicity artifacts.

Frequently Asked Questions

What is the difference between IC50 and EC50?

IC50 (half-maximal inhibitory concentration) measures the potency of an antagonist or inhibitor in reducing a biological response by 50%. EC50 (half-maximal effective concentration) measures the concentration of an agonist or drug that produces 50% of its maximal stimulatory effect.

Why is Cheng-Prusoff Ki conversion necessary instead of relying solely on IC50?

IC50 is an operational measurement that varies directly with experimental substrate concentration [S]. Higher substrate concentrations competitively displace the inhibitor, making the observed IC50 appear higher. The Cheng-Prusoff equation converts IC50 into Ki, which is an intrinsic thermodynamic affinity constant independent of substrate concentration.

What does a Hill slope (nH) significantly greater or less than 1.0 indicate?

A Hill slope of 1.0 reflects standard mass-action binding to a single independent site. Slopes > 1.5 suggest positive cooperativity or threshold mechanism, while slopes < 0.8 suggest negative cooperativity, multiple receptor subtypes, or solubility limitations.

How many concentration points should be included in an IC50 dose-response curve?

A minimum of 7 to 10 serial concentration points spanning at least 3 to 4 orders of magnitude is recommended, with multiple points defining both the lower and upper asymptotic plateaus.