Assay Optimization & Serial Pipetting
ELISA • Microbiology CFU • qPCR • IC50
DF = Total Vol / Transfer Vol

Serial Dilution Calculator (Multi-Step Dilution Protocol)

Design geometric serial dilution series for ELISA standard curves, microbiology colony counts, qPCR dynamic range, and IC50 dose-response assays. View transfer volumes, tube color gradients, and copy pipetting recipes.

Serial Dilution Setup

Quick Preset:

Concentration of Tube 1 (undiluted stock)

Fold dilution per step (e.g. 2 = 1:2, 10 = 1:10)

Total tubes or microplate wells

Target final volume in each well

Transfer Volume100 µL

Pipetted per step

Diluent Volume100 µL

Pre-loaded in tubes 2–8

Total Dynamic Range1 : 128

Across 8 dilution levels

Lowest Concentration7.81 µg/mL

Tube 8

Dilution Series Strip Preview

#1
100 µL
1000.0
µg/mL
1:1
+100 µL
#2
100 µL
500.0
µg/mL
1 : 2
+100 µL
#3
100 µL
250.0
µg/mL
1 : 4
+100 µL
#4
100 µL
125.0
µg/mL
1 : 8
+100 µL
#5
100 µL
62.50
µg/mL
1 : 16
+100 µL
#6
100 µL
31.25
µg/mL
1 : 32
+100 µL
#7
100 µL
15.63
µg/mL
1 : 64
+100 µL
#8
200 µL
7.81
µg/mL
1 : 128

Serial Dilution Pipetting & Concentration Table

Tube #Dilution RatioDilution FoldConcentrationLog₁₀[C]Transfer VolDiluent VolFinal Remaining Vol
Tube 1 (Stock)1:11.0x1000.0 µg/mL3.00--100 µL
Tube 2 1 : 22.0x500.0 µg/mL2.70100 µL100 µL100 µL
Tube 3 1 : 44.0x250.0 µg/mL2.40100 µL100 µL100 µL
Tube 4 1 : 88.0x125.0 µg/mL2.10100 µL100 µL100 µL
Tube 5 1 : 1616.0x62.50 µg/mL1.80100 µL100 µL100 µL
Tube 6 1 : 3232.0x31.25 µg/mL1.49100 µL100 µL100 µL
Tube 7 1 : 6464.0x15.63 µg/mL1.19100 µL100 µL100 µL
Tube 8 1 : 128128.0x7.81 µg/mL0.89100 µL100 µL200 µL

Serial Dilution Calculator Formulas & Mathematics

1. Step Dilution Factor (DF) Formula

The dilution factor for an individual transfer step is the ratio of final total volume to the aliquot volume transferred:

Dilution Factor (DF)=V_totalV_transfer=
V_transfer+V_diluent
V_transfer

For example, transferring 50 µL into 150 µL diluent gives a total volume of 200 µL, resulting in a 4-fold dilution (DF = 200 / 50 = 4, or a 1:4 dilution ratio).

2. Cumulative Dilution & Final Concentration

In a geometric serial dilution across n steps with constant dilution factor DF:

Cn=C0
DFn
=C0×(1DF)n

3. Dilution Ratio Terminology: 1:N vs. 1-to-N

In biological and biochemical literature, a "1:10 dilution" standardly designates 1 part stock diluted into 9 parts diluent for a total of 10 parts (10-fold dilution). Always confirm whether a protocol uses part-to-total (1:10) or part-to-part notation to prevent 10–20% systematic dosing errors.

Serial Dilution Pipetting Workflow & Discard Step Diagram

Standard 1:10 Serial Dilution Transfer Scheme (e.g. 100 µL into 900 µL)
Bench Protocol
Stock10⁰ (100%)+100 µLTube 110⁻¹ (1:10)+100 µLTube 210⁻² (1:100)+100 µLTube 310⁻³ (1:1k)+100 µLTube 410⁻⁴ (1:10k)Discard 100 µLWasteAll tubes maintain equal final working volume (e.g. 900 µL) for assay consistency
1. Pre-fill Diluent

Add 900 µL buffer to all tubes first.

2. Transfer & Change Tips

Transfer 100 µL, mix 5–8x, change tips.

3. Discard from Last Tube

Discard 100 µL from the final tube to match volume.

Serial Dilution Pipetting Protocol & Accuracy Tips

Change Pipette Tips Between Every Transfer

Never reuse the same pipette tip for consecutive transfers. Carryover of droplets adhering to the exterior of the tip can introduce compounding positive error of 15%–40% by the end of an 8-step series.

Pipette Mixing Thoroughness

Aspirate and dispense at least 5 to 8 times with the pipette set to 75% of the total well volume before transferring to the next well. Avoid generating bubbles or aerosols, which distort volume accuracy.

Discard Final Transfer for Equal Volumes

If your downstream plate reader or cell assay requires identical assay volumes across all wells, discard the transferred aliquot from the final tube so all wells contain equal volumes.

Key Experimental Applications

ELISA & Immunoassays (2-Fold or 3-Fold Series)

Standard curves typically span 7 or 8 points (e.g. 1000, 500, 250, 125, 62.5, 31.25, 15.63, 0 pg/mL) to ensure accurate fitting along the linear and 4-parameter logistic (4PL) dynamic detection range.

Microbiology CFU Plating (10-Fold Series)

Dilutions from 10⁻¹ down to 10⁻⁷ are spotted or spread on agar plates to yield countable colonies within the statistically valid range of 30 to 300 CFU per plate.

Pharmacology IC50 / Dose-Response (Half-Log Series)

Half-log dilutions (factor of 3.16, or 10^0.5) produce evenly spaced points on a logarithmic dose axis (e.g., 10 µM, 3.16 µM, 1 µM, 316 nM, 100 nM...), ideal for sigmoidal Hill curve fitting.

Frequently Asked Questions

What does a '1:10 dilution' mean in biological laboratory protocols?

In biology and biochemistry, a 1:10 dilution means 1 volume of stock added to 9 volumes of diluent for a total of 10 volumes (a 10-fold dilution factor). Always ensure whether a protocol means part-to-total or part-to-part.

Why must pipette tips be changed between serial dilution transfers?

Liquid clinging to the outside of a pipette tip carries over concentrated solute into subsequent dilution tubes. Failing to change tips introduces compounding positive concentration errors of 15% to 40% across an 8-step series.

How do half-log serial dilutions work for pharmacology and drug screening?

A half-log dilution uses a factor of √10 ≈ 3.162. Two successive half-log dilutions equal a 10-fold (1 log) reduction. This produces evenly spaced points on a logarithmic concentration scale, perfect for sigmoidal Hill dose-response curves.

Should I discard volume from the last tube in a serial dilution?

If your downstream assay requires uniform liquid volume across all wells (such as 100 µL per well in a 96-well ELISA or cell viability plate), discard the transferred volume from the final dilution tube so that all tubes retain identical volumes.